| تعداد نشریات | 21 |
| تعداد شمارهها | 667 |
| تعداد مقالات | 9,728 |
| تعداد مشاهده مقاله | 69,208,510 |
| تعداد دریافت فایل اصل مقاله | 48,536,530 |
Relative Assessment of Flame Characteristics and Pollutant Levels of Inverse Diffusion and Central Diffusion Flames | ||
| Journal of Heat and Mass Transfer Research | ||
| مقالات آماده انتشار، پذیرفته شده، انتشار آنلاین از تاریخ 17 آبان 1404 | ||
| نوع مقاله: Full Length Research Article | ||
| شناسه دیجیتال (DOI): 10.22075/jhmtr.2025.34971.1595 | ||
| نویسندگان | ||
| Ankit Chauhan1؛ Mayur Vadoliya1؛ Vipul Patel2؛ Rupesh Shah* 3 | ||
| 1Department of Mechanical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat | ||
| 2Mechanical Engineering Department, Government Engineering College, Dahod, India | ||
| 3Department of Mechanical Engineering, Sardar Vallabhbhai National Institute of technology, Surat | ||
| تاریخ دریافت: 17 مرداد 1403، تاریخ بازنگری: 17 مهر 1404، تاریخ پذیرش: 17 آبان 1404 | ||
| چکیده | ||
| Relative performance analysis in terms of flame shape, size, temperature distribution and pollutant levels of non-swirling turbulent, Inverse Diffusion Flame (IDF) and Central Diffusion Flame (CDF) is experimentally studied. Methane gas is used as fuel and air as an oxidizer. In IDF (two inlet system), air enters through the central tube and fuel through the outer coaxial tube. In CDF (three inlet system), another coaxial tube is added around the outer fuel tube and secondary air (annular) is supplied through it. In IDF and CDF, both mass flow rate of air (125 LPM) and mass flow rate of fuel (4 LPM) are kept constant in all cases. In CDF, secondary air flow rate is varied between 5 and 25 percent in 5 percent increments. Flame characteristics such as flame appearance, length, temperature distribution, and emission are measured and compared for IDF and CDF. Secondary air in CDF improves flame stability compared to IDF. Better stability is observed in CDF compared to IDF. Total flame length and blue zone length are less in CDF compared to IDF because the reaction zone shifts towards the flame base as the annular jet of CDF provides additional air for the combustion process. CO emission level decreases with increasing annular air fraction in CDFs. CDF with 10% annular air outperforms in terms of blue zone length, flame length, CO emissions and combustion noise. | ||
| کلیدواژهها | ||
| Central Diffusion Flame؛ Inverse Diffusion Flame؛ Flame Characteristics؛ Emissions؛ Combustion Noise | ||
|
آمار تعداد مشاهده مقاله: 5 |
||