Numerical study of fluid flow and heat transfer in a gas-tank water heater | ||
Journal of Heat and Mass Transfer Research | ||
مقاله 3، دوره 2، شماره 1 - شماره پیاپی 3، مرداد 2015، صفحه 21-29 اصل مقاله (884.17 K) | ||
نوع مقاله: Full Length Research Article | ||
شناسه دیجیتال (DOI): 10.22075/jhmtr.2015.336 | ||
نویسندگان | ||
Mohammad Hossein Tavakoli* ؛ Khatereh Moharramkhani | ||
Physics Department, Bu-Ali Sina University, Hamedan, Iran | ||
تاریخ دریافت: 13 فروردین 1393، تاریخ بازنگری: 16 خرداد 1393، تاریخ پذیرش: 05 مرداد 1393 | ||
چکیده | ||
Influence of a vent hood at the exit of exhaust flue gas and flue baffles in the fire tube on the temperature and flow fields of a gas tank water heater, as well as the structure and amount of heat transferred to the water tank has been studied numerically using two-dimensional steady state finite element simulation. Observations show that without a vent hood, there is a downward gas flow in the flue and a strong vortex in the lower burner chamber. Using a vent hood prevents the gas back flow into the flue, and placing the flue baffles increases the heat delivered to the water | ||
کلیدواژهها | ||
Fluid flow؛ Heat transfer؛ Tank water heater؛ Computer simulation | ||
مراجع | ||
[1]. M. Krarti, Energy Auditing of Building Systems – An Engineering Approach, CRC Press, (2000).
[3]. K.F. Michaelsen, K. Taudorf, Danger of Gas Water Heaters, the Lancet, 322,229-230, (1983).
[4]. W.R. Chang, C.L. Cheng, Carbon monoxide transport in an enclosed room with sources from a water heater in the adjacent balcony, Building and Environment, 43,861-870, (2008).
[5]. O. Aydin, Y.E. Boke, An experimental study on carbon monoxide emission reduction at a fire tube water heater, Applied Thermal Engineering, 30, 2658-2662, (2010).
[6]. G. Gutierrez, F. Hincapie, J.A. Duffie, W.A. Beckman, Simulation of forced circulation water heaters; effects of auxiliary energy supply, load type and storage capacity, Solar Energy, 15,287-298, (1974).
[7]. G.N. Tiwari, N.K. Dhiman, Effect of the baffle plate on transient performance of built-in-storage water heater, Energy Conversion and Management,23,151-155, (1983).
[8]. T.W. Abou-Arab, M.O. Othman, Y.H. Najjar, N.T. Ahmad, Combustion and heat transfer characteristics for a dual-fuel cylindrical water heater model,Fuel,69,485-489, (1990).
[9]. A.K. Kar, K.M. Al-Dossary, Thermal performances of water heaters in series, Applied Energy,52,47-53, (1995).
[10]. A.A. Hegazy, M.R. Diab, Performance of an improved design for storage-type domestic electrical water-heaters, Applied Energy,71,287-306, (2002).
[11]. M. Kim, M.S. Kim, J.D. Chung, Transient thermal behavior of a water heater system driven by a heat pump, International Journal of Refrigeration,27,415-421, (2004).
[12]. A.A. Hegazy Effect of inlet design on the performance of storage-type domestic electrical water heaters, Applied Energy, 84, 1338-1355, (2007).
[13]. D.S. Sowmy, R.T.A. Prado Assessment of energy efficiency in electric storage water heaters, Energy and Buildings, 40, 2128-2132, (2008).
[14]. S. Tajwar, A.R. Saleemi, N. Ramzan, S. Naveed Improving thermal and combustion efficiency of gas water heater, Applied Thermal Engineering,31,1305-1312, (2011).
[15]. M. MoeiniSedeh, J.M. Khodadadi Energy efficiency improvement and fuel savings in water heaters using baffles, Applied Energy, 102,520-533, (2013).
[16]. http://www.atlantarealestateinspection.com/
[17]. F.P. Incropera, D.P. De Witt Introduction to Heat Transfer, John Wiley and Sons,(1996).
[18]. I.H. Shames, Mechanics of Fluids, Mc-Graw-Hill, New York, (1982).
[19]. J.P. Holman, Heat Transfer, Mc-Graw-Hill, New York, (1990).
[21]. K. Moharramkhani, M.Sc. Thesis, Bu-Ali Sina University, (2010).
[22]. Technical Manual, T.M. 5-650Central Boiler Plants, Publications of the Headquarters, United States Army Corps of Engineers, (1989).
[23]. S.J. Craig, J.F. McMahon, The effects of draft control on combustion, ISA Transactions,35,345-349, (1996). | ||