Evaluation of Silica Fume on the Performance of Corroded Concrete with Bacteria Using NDT Methods | ||
| Journal of Rehabilitation in Civil Engineering | ||
| دوره 14، شماره 2 - شماره پیاپی 42، تابستان 2026 اصل مقاله (1.68 M) | ||
| نوع مقاله: Regular Paper | ||
| شناسه دیجیتال (DOI): 10.22075/jrce.2025.2266 | ||
| نویسندگان | ||
| Ahmad Zaki* 1؛ Muhammad Restu Riady Putra2؛ Sri Atmaja P. Rosyidi2؛ Abdullah M. Zeyad3؛ Kharisma Wira Nindhita1 | ||
| 1Magister of Civil Engineering, Universitas Muhammadiyah Yogyakarta, Bantul 55183, Special Region of Yogyakarta, Indonesia | ||
| 2Department of Civil Engineering, Faculty of Engineering, Universitas Muhammadiyah Yogyakarta, Indonesia | ||
| 3Civil and Architectural Engineering Department, College of Engineering and Computer Sciences, Jazan University, Jazan 45142, Saudi Arabia | ||
| چکیده | ||
| Silica fume can be used in place of cement to make reinforced concrete more resistant to corrosion. Cracks and corrosion can also be treated using Bacillus subtilis bacteria added to the mix. Using non-destructive testing, this study intends to ascertain the effects of silica fume addition to concrete bacteria on the mechanical and corrosion characteristics of the material. The beams and cylinders used in the tests were 50 x 10 x 10 cm3 and 30 x 15 cm3, respectively. In place of cement, the specimens had 8%, 10%, and 12% silica fume, and 10 ml (105 cfu/ml) of Bacillus subtilis bacteria were added. The direct current power supply is used in the accelerated corrosion process for 48, 96, and 168 hours. Regarding compressive strength, the typical concrete specimen tested at 37.59 MPa was the strongest. Silica fume concrete outperforms regular concrete in the flexural strength test. Compared to regular concrete, superior results were obtained from non-destructive tests conducted on silica fume concrete utilizing impact echo and resistivity instruments. The longer the concrete is exposed to corrosion, the lower the impact echo and resistivity values that are subsequently measured. By accelerating the corrosion process of silica fume concrete by 48, 96, and 168 hours, respectively, the impact echo and resistivity values for corrosion resistance reached their maximums of 12%, 10%, and 8%. | ||
تازه های تحقیق | ||
| ||
| کلیدواژهها | ||
| Silica Fume؛ Bacteria؛ Concrete؛ Corrosion؛ NDT | ||
| مراجع | ||
|
| ||
|
آمار تعداد مشاهده مقاله: 274 تعداد دریافت فایل اصل مقاله: 265 |
||
| تعداد نشریات | 22 |
| تعداد شمارهها | 718 |
| تعداد مقالات | 10,319 |
| تعداد مشاهده مقاله | 72,327,341 |
| تعداد دریافت فایل اصل مقاله | 64,053,353 |