تعداد نشریات | 21 |
تعداد شمارهها | 591 |
تعداد مقالات | 8,793 |
تعداد مشاهده مقاله | 66,730,981 |
تعداد دریافت فایل اصل مقاله | 7,297,859 |
A novel Electrokinetic Micromixing System with Conductive Mixing-Enclosure-A Geometrical Study | ||
Journal of Heat and Mass Transfer Research | ||
دوره 9، شماره 1 - شماره پیاپی 17، مرداد 2022، صفحه 65-76 اصل مقاله (1.45 M) | ||
نوع مقاله: Full Length Research Article | ||
شناسه دیجیتال (DOI): 10.22075/jhmtr.2022.21707.1314 | ||
نویسندگان | ||
Morteza Nazari1؛ Saman Rashidi* 2؛ Javad Abolfazli Esfahani1؛ Souad Harmand3 | ||
1Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad 91775-1111, Iran | ||
2Department of Energy, Faculty of New Science and Technologies, Semnan University, Semnan, Iran | ||
3Université Polytechnique Hauts-de-France, Laboratoire d’Automatique, de Mécanique et d’Informatique Industrielles et Humaines (LAMIH-UMR CNRS 8201), Valenciennes, F59313, France | ||
تاریخ دریافت: 13 آبان 1399، تاریخ بازنگری: 31 خرداد 1401، تاریخ پذیرش: 25 تیر 1401 | ||
چکیده | ||
In this paper, an electrokinetic micromixing system with conductive mixing-enclosure is proposed. The simulated micromixer can be fabricated easily and accordingly, it can be used in the microfluidic systems effectively. The mixing process is intensified by controlling the geometry of the mixing-enclosure and electric field strength. The effects of different parameters including existence of mixing-enclosure, horizontal and vertical sizes of mixing-enclosure, orientation angle of mixing-enclosure, and electric field strength on the mixing index are studied. The mixing efficiencies and mixing lengths of current electrokinetic micromixer and those previously proposed by other researchers are compared. The results showed that the mixing efficiency can be enhanced significantly as a micromixer with conductive mixing-enclosure is employed. As an advantage of the proposed micromixer, the maximum mixing efficiency does not change by boosting the electric field strength in the range of 100 V.cm-1 to 200 V.cm-1, while the mixing time diminishes as the electric field strength increases in this range. For the conductive mixing-enclosure with the orientation angle of 45°, maximum mixing efficiency of 96.6% is achieved by exerting electric field with strength of 75 V.cm-1. The current electrokinetic micromixer has superior mixing efficiency and mixing length as compared with other electrokinetic micromixers. | ||
کلیدواژهها | ||
Electrokinetic micromixer؛ Intensification؛ Mixing index؛ Electric field؛ Mixing-enclosure geometry | ||
عنوان مقاله [English] | ||
مطالعه هندسی روی یک سیستم ریز مخلوطگر الکتروکینتیک با محفظه اختلاط رسانا | ||
چکیده [English] | ||
در این مقاله، یک سیستم میکرو مخلوط گر الکتروکینتیک با محفظه اختلاط رسانا پیشنهاد شده است. میکرو مخلوط گر شبیه سازی شده می تواند به راحتی ساخته شود و بر این اساس، می تواند به طور موثری در سیستم های میکروفلوئیدیک استفاده شود. فرآیند اختلاط با کنترل هندسه محفظه اختلاط و شدت میدان الکتریکی تشدید می شود. اثرات پارامترهای مختلف از جمله وجود محفظه اختلاط، اندازه های افقی و عمودی محفظه اختلاط ، زاویه جهت محفظه اختلاط و شدت میدان الکتریکی بر شاخص اختلاط مورد مطالعه قرار گرفته است. راندمان اختلاط و طول اختلاط ریز مخلوط گر الکتروکینتیک فعلی و مخلوط گرهایی که قبلاً توسط سایر محققان ارائه شده اند مقایسه می شوند. نتایج نشان داد که می توان با استفاده مخلوط گر با محفظه اختلاط رسانا، راندمان اختلاط را به میزان قابل توجهی افزایش داد. به عنوان یک مزیت، حداکثر کارایی اختلاط ریز مخلوطگر پیشنهادی با افزایش قدرت میدان الکتریکی در محدوده 100 تا 1200 ولت بر سانتیمتر تغییر نمی کند در حالی که با افزایش قدرت میدان الکتریکی در این محدوده، زمان مخلوط شدن کاهش می یابد. برای محفظه اختلاط رسانا با زاویه جهت 45 درجه، حداکثر بازده اختلاط 96.6 درصدی با اعمال میدان الکتریکی با قدرت 75 ولت بر سانتی متر متر حاصل می شود. ریز مخلوطگر الکتروکینتیک فعلی در مقایسه با سایر ریز مخلوطگرهای الکتروکینتیک دارای کارایی و طول اختلاط بهتری است. | ||
کلیدواژهها [English] | ||
ریز مخلوطگر الکتروکینتیک؛ تشدید, شاخص اختلاط, میدان الکتریکی؛ هندسه محفظه اختلاط | ||
مراجع | ||
[1] Demello, A.J., 2006. Control and detection of chemical reactions in microfluidic systems. Nature, 442(7101), pp.394-402.
[2] Meagher, R.J., Hatch, A.V., Renzi, R.F. and Singh, A.K., 2008. An integrated microfluidic platform for sensitive and rapid detection of biological toxins. Lab on a Chip, 8(12), pp.2046-2053.
[3] Khetani, S.R. and Bhatia, S.N., 2008. Microscale culture of human liver cells for drug development. Nature biotechnology, 26(1), pp.120-126.
[4] Dittrich, P.S. and Manz, A., 2006. Lab-on-a-chip: microfluidics in drug discovery. Nature reviews Drug discovery, 5(3), pp.210-218.
[5] Anderson, R.C., Su, X., Bogdan, G.J. and Fenton, J., 2000. A miniature integrated device for automated multistep genetic assays. Nucleic acids research, 28(12), pp.e60-e60.
[6] Bayareh, M., Ashani, M.N. and Usefian, A., 2020. Active and passive micromixers: A comprehensive review. Chemical Engineering and Processing-Process Intensification, 147, p.107771.
[7] Bayareh, M., Usefian, A. and Ahmadi Nadooshan, A., 2019. Rapid mixing of Newtonian and non-Newtonian fluids in a three-dimensional micro-mixer using non-uniform magnetic field. Journal of Heat and Mass Transfer Research, 6(1), pp.55-61.
[8] Usefian, A. and Bayareh, M., 2020. Numerical and experimental investigation of an efficient convergent–divergent micromixer. Meccanica, 55(5), pp.1025-1035.
[9] Kang, D. K., et al., 2014. Rapid detection of single bacteria in unprocessed blood using Integrated Comprehensive Droplet Digital Detection. Nature Communications, vol. 5, pp. 1–10.
[10] Nguyen, D.P., Kloosterman, F., Barbieri, R., Brown, E.N., Wilson, M.A. and Klausberger, T., 2005. Z.: Micromixers–a review. In Journal of Micromechanics and Microengineering.
[11] Jahn, A., Stavis, S.M., Hong, J.S., Vreeland, W.N., DeVoe, D.L. and Gaitan, M., 2010. Microfluidic mixing and the formation of nanoscale lipid vesicles. ACS nano, 4(4), pp.2077-2087.
[12] Baheri Islami, S., Khezerloo, M. and Gharraei, R., 2017. The effect of chaotic advection on mixing degree and pressure drop of non-Newtonian fluids flow in curved micromixers. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 39(3), pp.813-831.
[13] Zhang, S. and Chen, X., 2018. A novel passive micromixer based on Koch fractal principle. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 40(10), pp.1-9.
[14] Stroock, A.D., Dertinger, S.K., Ajdari, A., Mezic, I., Stone, H.A. and Whitesides, G.M., 2002. Chaotic mixer for microchannels. Science, 295(5555), pp.647-651.
[15] Gray, B.L., Jaeggi, D., Mourlas, N.J., Van Drieenhuizen, B.P., Williams, K.R., Maluf, N.I. and Kovacs, G.T.A., 1999. Novel interconnection technologies for integrated microfluidic systems. Sensors and Actuators A: Physical, 77(1), pp.57-65.
[16] Yi, M. and Bau, H.H., 2003. The kinematics of bend-induced mixing in micro-conduits. International Journal of Heat and Fluid Flow, 24(5), pp.645-656.
[17] Ismagilov, R.F., Stroock, A.D., Kenis, P.J., Whitesides, G. and Stone, H.A., 2000. Experimental and theoretical scaling laws for transverse diffusive broadening in two-phase laminar flows in microchannels. Applied Physics Letters, 76(17), pp.2376-2378.
[18] Chen, X., Li, T., Zeng, H., Hu, Z. and Fu, B., 2016. Numerical and experimental investigation on micromixers with serpentine microchannels. International Journal of Heat and Mass Transfer, 98, pp.131-140.
[19] Lee, C.Y., Wang, W.T., Liu, C.C. and Fu, L.M., 2016. Passive mixers in microfluidic systems: A review. Chemical Engineering Journal, 288, pp.146-160.
[20] Aoki, N. and Mae, K., 2006. Effects of channel geometry on mixing performance of micromixers using collision of fluid segments. Chemical Engineering Journal, 118(3), pp.189-197.
[21] Yaralioglu, G.G., Wygant, I.O., Marentis, T.C. and Khuri-Yakub, B.T., 2004. Ultrasonic mixing in microfluidic channels using integrated transducers. Analytical chemistry, 76(13), pp.3694-3698.
[22] Mao, H., Yang, T. and Cremer, P.S., 2002. A microfluidic device with a linear temperature gradient for parallel and combinatorial measurements. Journal of the American Chemical Society, 124(16), pp.4432-4435.
[23] Ma, Y., Sun, C.P., Fields, M., Li, Y., Haake, D.A., Churchill, B.M. and Ho, C.M., 2008. An unsteady microfluidic T-form mixer perturbed by hydrodynamic pressure. Journal of Micromechanics and Microengineering, 18(4), p.045015.
[24] Lu, L.H., Ryu, K.S. and Liu, C., 2002. A magnetic microstirrer and array for microfluidic mixing. Journal of microelectromechanical systems, 11(5), pp.462-469.
[25] Suzuki, H. and Ho, C.M., 2002, January. A magnetic force driven chaotic micro-mixer. In Technical Digest. MEMS 2002 IEEE International Conference. Fifteenth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No. 02CH37266) (pp. 40-43). IEEE.
[26] Nazari, M., Rashidi, S. and Esfahani, J.A., 2020. Effects of flexibility of conductive plate on efficiency of an induced-charge electrokinetic micro-mixer under constant and time-varying electric fields-a comprehensive parametric study. Chemical Engineering Science, 212, p.115335.
[27] Nazari, M., Chuang, P.Y.A., Esfahani, J.A. and Rashidi, S., 2020. A comprehensive geometrical study on an induced-charge electrokinetic micromixer equipped with electrically conductive plates. International Journal of Heat and Mass Transfer, 146, p.118892.
[28] Azimi, S., Nazari, M. and Daghighi, Y., 2016. Fluid physics around conductive deformable flaps within an induced-charge electrokinetically driven microsystem. Microfluidics and Nanofluidics, 20(9), pp.1-16.
[29] Azimi, S., Nazari, M. and Daghighi, Y., 2017. Developing a fast and tunable micro-mixer using induced vortices around a conductive flexible link. Physics of Fluids, 29(3), p.032004.
[30] Daghighi, Y., Gao, Y. and Li, D., 2011. 3D numerical study of induced-charge electrokinetic motion of heterogeneous particle in a microchannel. Electrochimica acta, 56(11), pp.4254-4262.
[31] Daghighi, Y. and Li, D., 2013. Numerical study of a novel induced-charge electrokinetic micro-mixer. Analytica chimica acta, 763, pp.28-37.
[32] Usefian, A., Bayareh, M., Shateri, A. and Taheri, N., 2019. Numerical study of electro-osmotic micro-mixing of Newtonian and non-Newtonian fluids. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 41(5), pp.1-10.
[33] Usefian, A. and Bayareh, M., 2019. Numerical and experimental study on mixing performance of a novel electro-osmotic micro-mixer. Meccanica, 54(8), pp.1149-1162.
[34] Saha, S., Gopmandal, P.P. and Ohshima, H., 2019. Electroosmotic flow and transport of ionic species through a slit soft nanochannel filled with general electrolytes. Meccanica, 54(14), pp.2131-2149.
[35] Qi, C. and Ng, C.O., 2018. Rotating electroosmotic flow in a non-uniform microchannel. Meccanica, 53(8), pp.2105-2120.
[36] Tsai, J.H. and Lin, L., 2002. Active microfluidic mixer and gas bubble filter driven by thermal bubble micropump. Sensors and Actuators A: Physical, 97, pp.665-671.
[37] Zhao, H. and Bau, H.H., 2007. Microfluidic chaotic stirrer utilizing induced-charge electro-osmosis. Physical Review E, 75(6), p.066217.
[38] Wu, Z. and Li, D., 2008. Micromixing using induced-charge electrokinetic flow. Electrochimica Acta, 53(19), pp.5827-5835.
[39] Helmholtz, H., Der phystk und chemie. 1. no. 2, 1853.
[40] Dukhin, A.S. and Goetz, P.J., 2010. Fundamentals of interface and colloid science. In Studies in Interface Science (Vol. 24, pp. 21-89). Elsevier.
[41] Wu, Z. and Li, D., 2008. Mixing and flow regulating by induced-charge electrokinetic flow in a microchannel with a pair of conducting triangle hurdles. Microfluidics and nanofluidics, 5(1), pp.65-76. | ||
آمار تعداد مشاهده مقاله: 360 تعداد دریافت فایل اصل مقاله: 210 |